AH1
SPECIFICATIONS
1. Contact rating (resistive load)
Standard rating
Minimum rating
Standard type
Low-level circuit type
O.F. 0.74N
O.F. 1.47N
1A 125V AC, 1A 30V DC
3A 125V AC, 2A 30V DC
0.1A 125V AC, 0.1A 30V DC
—
—
5mA 6V DC, 2mA 12V DC, 1mA 24V DC
2. Characteristics
Contact arrangement
Expected life (Min. operations)
Electrical (at rated load, 20 cpm) (O.T.: Max.)
Expected life (Min. operations)
Mechanical (at 60 cpm) (O.T.: Speci?ed value)
Dielectric strength (initial)
Between terminals
Between terminals and other exposed parts
Between terminals and ground
Insulation resistance (Min. at 500V DC)
Standard type
3 × 10 4
O.F. 0.74 N: 10 6
O.F. 1.47 N: 5 × 10 5
600 Vrms for 1 min.
1,500 Vrms for 1 min.
1,500 Vrms for 1 min.
100 M ?
Low-level circuit type
10 5
Initial contact resistance
Max. 30 m ?
(by voltage drop, 1A 6 to 8V DC)
Max. 100 m ?
(by voltage drop, 0.1A 6 to 8V DC)
Allowable operating speed (No load)
Max. operating cycle rate (No load)
Ambient temperature
Shock resistance (Pin plunger type)
Vibration resistance (Pin pluger type)
3. Operating characteristics
1) Pin plunger
1 to 500 mm/sec.
120 cpm
–25 to +85 ° C (Not freezing below 0 ° C)
Min. 294 m/s 2 (Contact opening: Max. 1 msec.)
10 to 55 Hz at single amplitude of 0.75mm (Contact opening: Max. 1 msec.)
3th digit of
Part No.
Operating force,
Max.
Release force,
Min.
Pretravel, Max.
mm
Movement
differential, Max.
mm
Overtravel,
Min. mm
Operating position mm
7 ± 0.3
6
0.47 N
0.20 N
(Distance from stand off)
5.5 ± 0.2
0.5
0.12
0.25
(Distance from mounting hole)
7 ± 0.3
8
0.74 N
0.098 N
(Distance from stand off)
5.5 ± 0.2
(Distance from mounting hole)
2) Hinge lever
3th digit of
Part No.
Operating force,
Max.
Release force,
Min.
Pretravel, Max.
mm
Movement
differential, Max.
mm
Overtravel,
Min. mm
Operating position mm
8.3 ± 1.2
6
0.49 N
0.049 N
(Distance from stand off)
6.8 ± 1.0
2.1
0.5
0.55
(Distance from mounting hole)
8.3 ± 1.2
8
0.25 N
0.025 N
(Distance from stand off)
6.8 ± 1.0
(Distance from mounting hole)
3) Simulated roller lever
3th digit of
Part No.
Operating force,
Max.
Release force,
Min.
Pretravel, Max.
mm
Movement
differential, Max.
mm
Overtravel,
Min. mm
Operating position mm
11.0 ± 1.2
6
0.54 N
0.039 N
(Distance from stand off)
9.5 ± 1.0
2.1
0.5
0.5
(Distance from mounting hole)
11.0 ± 1.2
8
0.26 N
0.020 N
(Distance from stand off)
9.5 ± 1.0
(Distance from mounting hole)
AECTB15E 201201-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e